61970-600-2_Equipment-AP-Con-Complex-InverseAssociation-SHACL
eq301ia:BusNameMarker
Severity: sh:Violation
Targets:
- targetClass: cim:BusNameMarker
Nested Properties:
eq301ia:BusNameMarker.Terminal-cardinality
Path: ^cim:ACDCTerminal.BusNameMarker
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:CAESPlant
Severity: sh:Violation
Targets:
- targetClass: cim:CAESPlant
Nested Properties:
eq301ia:CAESPlant.ThermalGeneratingUnit-cardinality
Path: ^cim:ThermalGeneratingUnit.CAESPlant
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:ConformLoadGroup
Severity: sh:Violation
Targets:
- targetClass: cim:ConformLoadGroup
Nested Properties:
eq301ia:ConformLoadGroup.EnergyConsumers-cardinality
Path: ^cim:ConformLoad.LoadGroup
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:ConnectivityNode
Severity: sh:Violation
Targets:
- targetClass: cim:ConnectivityNode
Nested Properties:
eq301ia:ConnectivityNode.BoundaryPoint-cardinality
Path: ^cim100:BoundaryPoint.ConnectivityNode
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:Curve
Severity: sh:Violation
Targets:
- targetClass: cim:GrossToNetActivePowerCurve
- targetClass: cim:ReactiveCapabilityCurve
- targetClass: cim:VsCapabilityCurve
Nested Properties:
eq301ia:Curve.CurveDatas-cardinality
Path: ^cim:CurveData.Curve
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:EnergyArea
Severity: sh:Violation
Targets:
- targetClass: cim:SubLoadArea
- targetClass: cim:LoadArea
Nested Properties:
eq301ia:EnergyArea.ControlArea-cardinality
Path: ^cim:ControlArea.EnergyArea
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:GeneratingUnit
Severity: sh:Violation
Targets:
- targetClass: cim:GeneratingUnit
- targetClass: cim:HydroGeneratingUnit
- targetClass: cim:NuclearGeneratingUnit
- targetClass: cim:SolarGeneratingUnit
- targetClass: cim:ThermalGeneratingUnit
- targetClass: cim:WindGeneratingUnit
Nested Properties:
eq301ia:GeneratingUnit.RotatingMachine-cardinality
Path: ^cim:RotatingMachine.GeneratingUnit
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:LoadArea
Severity: sh:Violation
Targets:
- targetClass: cim:LoadArea
Nested Properties:
eq301ia:LoadArea.SubLoadAreas-cardinality
Path: ^cim:SubLoadArea.LoadArea
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:NonConformLoadGroup
Severity: sh:Violation
Targets:
- targetClass: cim:NonConformLoadGroup
Nested Properties:
eq301ia:NonConformLoadGroup.EnergyConsumers-cardinality
Path: ^cim:NonConformLoad.LoadGroup
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:NonlinearShuntCompensator
Severity: sh:Violation
Targets:
- targetClass: cim:NonlinearShuntCompensator
Nested Properties:
eq301ia:NonlinearShuntCompensator.NonlinearShuntCompensatorPoints-cardinality
Path: ^cim:NonlinearShuntCompensatorPoint.NonlinearShuntCompensator
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:PhaseTapChangerTable
Severity: sh:Violation
Targets:
- targetClass: cim:PhaseTapChangerTable
Nested Properties:
eq301ia:PhaseTapChangerTable.PhaseTapChangerTablePoint-cardinality
Path: ^cim:PhaseTapChangerTablePoint.PhaseTapChangerTable
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:PowerElectronicsUnit
Severity: sh:Violation
Targets:
- targetClass: cim:PowerElectronicsWindUnit
- targetClass: cim:PhotoVoltaicUnit
- targetClass: cim:BatteryUnit
Nested Properties:
eq301ia:PowerElectronicsUnit.PowerElectronicsConnection-cardinality
Path: ^cim:PowerElectronicsConnection.PowerElectronicsUnit
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:RatioTapChangerTable
Severity: sh:Violation
Targets:
- targetClass: cim:RatioTapChangerTable
Nested Properties:
eq301ia:RatioTapChangerTable.RatioTapChangerTablePoint-cardinality
Path: ^cim:RatioTapChangerTablePoint.RatioTapChangerTable
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:ReactiveCapabilityCurve
Severity: sh:Violation
Targets:
- targetClass: cim:ReactiveCapabilityCurve
Nested Properties:
eq301ia:ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines-cardinality
Path: ^cim:SynchronousMachine.InitialReactiveCapabilityCurve
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:RegularIntervalSchedule
Severity: sh:Violation
Targets:
- targetClass: cim:ConformLoadSchedule
- targetClass: cim:NonConformLoadSchedule
- targetClass: cim:RegulationSchedule
- targetClass: cim:SwitchSchedule
- targetClass: cim:TapSchedule
Nested Properties:
eq301ia:RegularIntervalSchedule.TimePoints-cardinality
Path: ^cim:RegularTimePoint.IntervalSchedule
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:RotatingMachine
Severity: sh:Violation
Targets:
- targetClass: cim:SynchronousMachine
- targetClass: cim:AsynchronousMachine
Nested Properties:
eq301ia:RotatingMachine.HydroPump-cardinality
Path: ^cim:HydroPump.RotatingMachine
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:SubLoadArea
Severity: sh:Violation
Targets:
- targetClass: cim:SubLoadArea
Nested Properties:
eq301ia:SubLoadArea.LoadGroups-cardinality
Path: ^cim:LoadGroup.SubLoadArea
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:TapChangerControl
Severity: sh:Violation
Targets:
- targetClass: cim:TapChangerControl
Nested Properties:
eq301ia:TapChangerControl.TapChanger-cardinality
Path: ^cim:TapChanger.TapChangerControl
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MinCountConstraintComponent (Severity: sh:Violation)
- MinCount:
1
- MinCount:
eq301ia:Terminal
Severity: sh:Violation
Targets:
- targetClass: cim:Terminal
Nested Properties:
eq301ia:Terminal.TieFlow-cardinality
Path: ^cim:TieFlow.Terminal
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
2
- MaxCount:
eq301ia:TransformerEnd
Severity: sh:Violation
Targets:
- targetClass: cim:PowerTransformerEnd
Nested Properties:
eq301ia:TransformerEnd.PhaseTapChanger-cardinality
Path: ^cim:PhaseTapChanger.TransformerEnd
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount:
eq301ia:TransformerEnd.RatioTapChanger-cardinality
Path: ^cim:RatioTapChanger.TransformerEnd
This constraint validates the cardinality of the association at the inverse direction.
Severity: sh:Violation
Messages:
- "Wrong number of associated instances."
Constraints:
- sh:MaxCountConstraintComponent (Severity: sh:Violation)
- MaxCount:
1
- MaxCount: