WindRefFrameRotIEC

Reference frame rotation model. Reference: IEC 61400-27-1:2015, 5.6.3.5.

Inheritance

Attributes

LabelTypeMultiplicityComment
WindTurbineType3or4IECWindTurbineType3or4IEC1Wind turbine type 3 or type 4 model with which this reference frame rotation model is associated.
tpllFloat1..1Time constant for PLL first order filter model (TPLL) (>= 0). It is a type-dependent parameter.
upll1Float1..1Voltage below which the angle of the voltage is filtered and possibly also frozen (uPLL1). It is a type-dependent parameter.