Skip to main content

ProprietaryParameterDynamics

Supports definition of one or more parameters of several different datatypes for use by proprietary user-defined models. This class does not inherit from IdentifiedObject since it is not intended that a single instance of it be referenced by more than one proprietary user-defined model instance.

Attributes

LabelTypeMultiplicityComment
AsynchronousMachineUserDefinedAsynchronousMachineUserDefined0..1Proprietary user-defined model with which this parameter is associated.
CSCUserDefinedCSCUserDefined0..1Proprietary user-defined model with which this parameter is associated.
DiscontinuousExcitationControlUserDefinedDiscontinuousExcitationControlUserDefined0..1Proprietary user-defined model with which this parameter is associated.
ExcitationSystemUserDefinedExcitationSystemUserDefined0..1Proprietary user-defined model with which this parameter is associated.
LoadUserDefinedLoadUserDefined0..1Proprietary user-defined model with which this parameter is associated.
MechanicalLoadUserDefinedMechanicalLoadUserDefined0..1Proprietary user-defined model with which this parameter is associated.
OverexcitationLimiterUserDefinedOverexcitationLimiterUserDefined0..1Proprietary user-defined model with which this parameter is associated.
PFVArControllerType1UserDefinedPFVArControllerType1UserDefined0..1Proprietary user-defined model with which this parameter is associated.
PFVArControllerType2UserDefinedPFVArControllerType2UserDefined0..1Proprietary user-defined model with which this parameter is associated.
PowerSystemStabilizerUserDefinedPowerSystemStabilizerUserDefined0..1Proprietary user-defined model with which this parameter is associated.
SVCUserDefinedSVCUserDefined0..1Proprietary user-defined model with which this parameter is associated.
SynchronousMachineUserDefinedSynchronousMachineUserDefined0..1Proprietary user-defined model with which this parameter is associated.
TurbineGovernorUserDefinedTurbineGovernorUserDefined0..1Proprietary user-defined model with which this parameter is associated.
TurbineLoadControllerUserDefinedTurbineLoadControllerUserDefined0..1Proprietary user-defined model with which this parameter is associated.
UnderexcitationLimiterUserDefinedUnderexcitationLimiterUserDefined0..1Proprietary user-defined model with which this parameter is associated.
VSCUserDefinedVSCUserDefined0..1Proprietary user-defined model with which this parameter is associated.
VoltageAdjusterUserDefinedVoltageAdjusterUserDefined0..1Proprietary user-defined model with which this parameter is associated.
VoltageCompensatorUserDefinedVoltageCompensatorUserDefined0..1Proprietary user-defined model with which this parameter is associated.
WindPlantUserDefinedWindPlantUserDefined0..1Proprietary user-defined model with which this parameter is associated.
WindType1or2UserDefinedWindType1or2UserDefined0..1Proprietary user-defined model with which this parameter is associated.
WindType3or4UserDefinedWindType3or4UserDefined0..1Proprietary user-defined model with which this parameter is associated.
booleanParameterValueBoolean0..1Boolean parameter value. If this attribute is populated, integerParameterValue and floatParameterValue will not be.
floatParameterValueFloat0..1Floating point parameter value. If this attribute is populated, booleanParameterValue and integerParameterValue will not be.
integerParameterValueInteger0..1Integer parameter value. If this attribute is populated, booleanParameterValue and floatParameterValue will not be.
parameterNumberInteger1..1Sequence number of the parameter among the set of parameters associated with the related proprietary user-defined model.