Skip to main content

PowerElectronicsConnection

A connection to the AC network for energy production or consumption that uses power electronics rather than rotating machines.

Inheritance

Attributes

LabelTypeMultiplicityComment
PowerElectronicsUnitPowerElectronicsUnit0..1An AC network connection may have several power electronics units connecting through it.
WindTurbineType3or4DynamicsWindTurbineType3or4Dynamics0..1The wind turbine type 3 or type 4 dynamics model associated with this power electronics connection.
maxQFloat0..1Maximum reactive power limit. This is the maximum (nameplate) limit for the unit.
minQFloat0..1Minimum reactive power limit for the unit. This is the minimum (nameplate) limit for the unit.
pFloat1..1Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution.
qFloat1..1Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution.
ratedSFloat0..1Nameplate apparent power rating for the unit. The attribute shall have a positive value.
ratedUFloat0..1Rated voltage (nameplate data, Ur in IEC 60909-0). It is primarily used for short circuit data exchange according to IEC 60909. The attribute shall be a positive value.