Skip to main content

GovSteamFV4

Detailed electro-hydraulic governor for steam unit.

Inheritance

Attributes

LabelTypeMultiplicityComment
cpsmnFloat1..1Minimum value of pressure regulator output (Cpsmn). Typical value = -1.
cpsmxFloat1..1Maximum value of pressure regulator output (Cpsmx). Typical value = 1.
crmnFloat1..1Minimum value of regulator set-point (Crmn). Typical value = 0.
crmxFloat1..1Maximum value of regulator set-point (Crmx). Typical value = 1,2.
kdcFloat1..1Derivative gain of pressure regulator (Kdc). Typical value = 1.
kf1Float1..1Frequency bias (reciprocal of droop) (Kf1). Typical value = 20.
kf3Float1..1Frequency control (reciprocal of droop) (Kf3). Typical value = 20.
khpFloat1..1Fraction of total turbine output generated by HP part (Khp). Typical value = 0,35.
kicFloat1..1Integral gain of pressure regulator (Kic). Typical value = 0,0033.
kipFloat1..1Integral gain of pressure feedback regulator (Kip). Typical value = 0,5.
kitFloat1..1Integral gain of electro-hydraulic regulator (Kit). Typical value = 0,04.
kmp1Float1..1First gain coefficient of intercept valves characteristic (Kmp1). Typical value = 0,5.
kmp2Float1..1Second gain coefficient of intercept valves characteristic (Kmp2). Typical value = 3,5.
kpcFloat1..1Proportional gain of pressure regulator (Kpc). Typical value = 0,5.
kppFloat1..1Proportional gain of pressure feedback regulator (Kpp). Typical value = 1.
kptFloat1..1Proportional gain of electro-hydraulic regulator (Kpt). Typical value = 0,3.
krcFloat1..1Maximum variation of fuel flow (Krc). Typical value = 0,05.
kshFloat1..1Pressure loss due to flow friction in the boiler tubes (Ksh). Typical value = 0,08.
lpiFloat1..1Maximum negative power error (Lpi). Typical value = -0,15.
lpsFloat1..1Maximum positive power error (Lps). Typical value = 0,03.
mnefFloat1..1Lower limit for frequency correction (MNEF). Typical value = -0,05.
mxefFloat1..1Upper limit for frequency correction (MXEF). Typical value = 0,05.
pr1Float1..1First value of pressure set point static characteristic (Pr1). Typical value = 0,2.
pr2Float1..1Second value of pressure set point static characteristic, corresponding to Ps0 = 1,0 PU (Pr2). Typical value = 0,75.
psmnFloat1..1Minimum value of pressure set point static characteristic (Psmn). Typical value = 1.
rsmimnFloat1..1Minimum value of integral regulator (Rsmimn). Typical value = 0.
rsmimxFloat1..1Maximum value of integral regulator (Rsmimx). Typical value = 1,1.
rvgmnFloat1..1Minimum value of integral regulator (Rvgmn). Typical value = 0.
rvgmxFloat1..1Maximum value of integral regulator (Rvgmx). Typical value = 1,2.
srmnFloat1..1Minimum valve opening (Srmn). Typical value = 0.
srmxFloat1..1Maximum valve opening (Srmx). Typical value = 1,1.
srsmpFloat1..1Intercept valves characteristic discontinuity point (Srsmp). Typical value = 0,43.
svmnFloat1..1Maximum regulator gate closing velocity (Svmn). Typical value = -0,0333.
svmxFloat1..1Maximum regulator gate opening velocity (Svmx). Typical value = 0,0333.
taFloat1..1Control valves rate opening time (Ta) (>= 0). Typical value = 0,8.
tamFloat1..1Intercept valves rate opening time (Tam) (>= 0). Typical value = 0,8.
tcFloat1..1Control valves rate closing time (Tc) (>= 0). Typical value = 0,5.
tcmFloat1..1Intercept valves rate closing time (Tcm) (>= 0). Typical value = 0,5.
tdcFloat1..1Derivative time constant of pressure regulator (Tdc) (>= 0). Typical value = 90.
tf1Float1..1Time constant of fuel regulation (Tf1) (>= 0). Typical value = 10.
tf2Float1..1Time constant of steam chest (Tf2) (>= 0). Typical value = 10.
thpFloat1..1High pressure (HP) time constant of the turbine (Thp) (>= 0). Typical value = 0,15.
tmpFloat1..1Low pressure (LP) time constant of the turbine (Tmp) (>= 0). Typical value = 0,4.
trhFloat1..1Reheater time constant of the turbine (Trh) (>= 0). Typical value = 10.
tvFloat1..1Boiler time constant (Tv) (>= 0). Typical value = 60.
tyFloat1..1Control valves servo time constant (Ty) (>= 0). Typical value = 0,1.
yFloat1..1Coefficient of linearized equations of turbine (Stodola formulation) (Y). Typical value = 0,13.
yhpmnFloat1..1Minimum control valve position (Yhpmn). Typical value = 0.
yhpmxFloat1..1Maximum control valve position (Yhpmx). Typical value = 1,1.
ympmnFloat1..1Minimum intercept valve position (Ympmn). Typical value = 0.
ympmxFloat1..1Maximum intercept valve position (Ympmx). Typical value = 1,1.