Skip to main content

GovSteamCC

Cross compound turbine governor. Unlike tandem compound units, cross compound units are not on the same shaft.

Inheritance​

Attributes​

LabelTypeMultiplicityComment
dhpFloat1..1HP damping factor (Dhp). Typical value = 0.
dlpFloat1..1LP damping factor (Dlp). Typical value = 0.
fhpFloat1..1Fraction of HP power ahead of reheater (Fhp). Typical value = 0,3.
flpFloat1..1Fraction of LP power ahead of reheater (Flp). Typical value = 0,7.
mwbaseFloat1..1Base for power values (MWbase) (> 0). Unit = MW.
pmaxhpFloat1..1Maximum HP value position (Pmaxhp). Typical value = 1.
pmaxlpFloat1..1Maximum LP value position (Pmaxlp). Typical value = 1.
rhpFloat1..1HP governor droop (Rhp) (> 0). Typical value = 0,05.
rlpFloat1..1LP governor droop (Rlp) (> 0). Typical value = 0,05.
t1hpFloat1..1HP governor time constant (T1hp) (>= 0). Typical value = 0,1.
t1lpFloat1..1LP governor time constant (T1lp) (>= 0). Typical value = 0,1.
t3hpFloat1..1HP turbine time constant (T3hp) (>= 0). Typical value = 0,1.
t3lpFloat1..1LP turbine time constant (T3lp) (>= 0). Typical value = 0,1.
t4hpFloat1..1HP turbine time constant (T4hp) (>= 0). Typical value = 0,1.
t4lpFloat1..1LP turbine time constant (T4lp) (>= 0). Typical value = 0,1.
t5hpFloat1..1HP reheater time constant (T5hp) (>= 0). Typical value = 10.
t5lpFloat1..1LP reheater time constant (T5lp) (>= 0). Typical value = 10.